■ Detection target gas: Switchable between two types of flammable gases (city gas, LPG) ■ Detection principle: Thermal wire type semiconductor ■ Detectable leakage amount: 3.3×10⁻⁶ Pa·m³/s ■ Detectable concentration: 10 ppm ■ Response time: Within 3 seconds ■ Detection indication: Intermittent sound and flashing alarm lamp ■ Power supply: Two AA alkaline batteries ■ Continuous usage time: Approximately 12 hours ■ Operating temperature and humidity range: -20 to +50°C, 30 to 85% RH or less (no condensation) ■ External dimensions: W38×H130×D32 mm (excluding protrusions) ■ Weight (including batteries): Approximately 190 g (including batteries and case) | ■ Gas leak inspection of outdoor and indoor pipes ■ Gas leak detection in indoor piping, gas valves, and rubber hoses ■ Gas leak detection at pipe joints and other areas | ||
■Calibration Gas: Methane ■Detection Principle: Contact combustion type ■Gas Sampling Method: Automatic suction type ■Measurement Range: 0–100% LEL ■Indication Accuracy: ±5% of full scale ■Alarm Setting Value: 20% LEL ■Alarm Method: ・Gas Alarm: Buzzer, red lamp flashing ・Fault Alarm: Buzzer, red lamp flashing, LCD display ■Operating Temperature Range: 0–40℃ ■Power Supply: Four AA alkaline batteries ■Continuous Operating Time: Approximately 20 hours (no alarm, 20℃, backlight OFF) ■Explosion-Proof Structure: Intrinsically safe explosion-proof structure (Exibd2CT3), sensor part is pressure-resistant explosion-proof structure ■Dimensions: W82×H162×D36mm (excluding protrusions) ■Weight (including batteries): Approximately 450g (excluding dry batteries) | For more details, please download the PDF from our website or feel free to contact us. | ||
■Target Gas for Detection Calibration Gas: Isobutane (Target Gases: Hydrogen, Xylene, Ethanol, Toluene) ■Detection Principle: Contact Combustion Type ■Gas Sampling Method: Automatic Suction Type ■Measurement Range: 0–100% LEL ■Indication Accuracy: ±5% of Full Scale ■Alarm Setting Value: 20% LEL ■Alarm Method - Gas Alarm: Buzzer, Red Lamp Flashing - Fault Alarm: Buzzer, Red Lamp Flashing, LCD Display ■Operating Temperature Range: -20 to +50°C ■Power Supply: Four AA Alkaline Batteries ■Continuous Operating Time: Approximately 20 hours (No Alarm, 20°C, Backlight OFF) ■Explosion-Proof Structure: Intrinsically Safe Explosion-Proof Structure (Exibd2CT3), Sensor Part is Pressure-Resistant Explosion-Proof Structure ■External Dimensions: W82×H162×D36mm (excluding protrusions) ■Weight (including batteries): Approximately 450g (excluding dry batteries) | For more details, please download the PDF from our company website or feel free to contact us. | ||
---
--- |
--- |
-
- Featured Products
-
Flammable Gas Detector 'XP-702 3-A' [Rental]
- overview
- ■ Detection target gas: Switchable between two types of flammable gases (city gas, LPG) ■ Detection principle: Thermal wire type semiconductor ■ Detectable leakage amount: 3.3×10⁻⁶ Pa·m³/s ■ Detectable concentration: 10 ppm ■ Response time: Within 3 seconds ■ Detection indication: Intermittent sound and flashing alarm lamp ■ Power supply: Two AA alkaline batteries ■ Continuous usage time: Approximately 12 hours ■ Operating temperature and humidity range: -20 to +50°C, 30 to 85% RH or less (no condensation) ■ External dimensions: W38×H130×D32 mm (excluding protrusions) ■ Weight (including batteries): Approximately 190 g (including batteries and case)
- Application/Performance example
- ■ Gas leak inspection of outdoor and indoor pipes ■ Gas leak detection in indoor piping, gas valves, and rubber hoses ■ Gas leak detection at pipe joints and other areas
Flammable Gas Detector Cosmo Techter XP-3110 (Methane) Rental
- overview
- ■Calibration Gas: Methane ■Detection Principle: Contact combustion type ■Gas Sampling Method: Automatic suction type ■Measurement Range: 0–100% LEL ■Indication Accuracy: ±5% of full scale ■Alarm Setting Value: 20% LEL ■Alarm Method: ・Gas Alarm: Buzzer, red lamp flashing ・Fault Alarm: Buzzer, red lamp flashing, LCD display ■Operating Temperature Range: 0–40℃ ■Power Supply: Four AA alkaline batteries ■Continuous Operating Time: Approximately 20 hours (no alarm, 20℃, backlight OFF) ■Explosion-Proof Structure: Intrinsically safe explosion-proof structure (Exibd2CT3), sensor part is pressure-resistant explosion-proof structure ■Dimensions: W82×H162×D36mm (excluding protrusions) ■Weight (including batteries): Approximately 450g (excluding dry batteries)
- Application/Performance example
- For more details, please download the PDF from our website or feel free to contact us.
Flammable Gas Detector Cosmo Protector 'XP-3110' [Rental]
- overview
- ■Target Gas for Detection Calibration Gas: Isobutane (Target Gases: Hydrogen, Xylene, Ethanol, Toluene) ■Detection Principle: Contact Combustion Type ■Gas Sampling Method: Automatic Suction Type ■Measurement Range: 0–100% LEL ■Indication Accuracy: ±5% of Full Scale ■Alarm Setting Value: 20% LEL ■Alarm Method - Gas Alarm: Buzzer, Red Lamp Flashing - Fault Alarm: Buzzer, Red Lamp Flashing, LCD Display ■Operating Temperature Range: -20 to +50°C ■Power Supply: Four AA Alkaline Batteries ■Continuous Operating Time: Approximately 20 hours (No Alarm, 20°C, Backlight OFF) ■Explosion-Proof Structure: Intrinsically Safe Explosion-Proof Structure (Exibd2CT3), Sensor Part is Pressure-Resistant Explosion-Proof Structure ■External Dimensions: W82×H162×D36mm (excluding protrusions) ■Weight (including batteries): Approximately 450g (excluding dry batteries)